Alarm Maintenance Checklist
- DATE CHECKED
- LINE & SERIAL #
- PLACE SYSTEM ON TEST AT MONITORING CENTRE
- CHECK EMERGENCY CONTACTS AND PHONE NUMBERS IN MASWEB
- ISOLATE PANEL TAMPER – TEMPORARILY DIABLE SIRENS
- CHECK INDICATOR LAMPS & CODE PAD FOR CORRECT OPERATION
- INSPECT ALL EQUIPMENT FOR DAMAGE OR POTENTIAL PROBLEMS & RECORD
- CHECK COMMUNICATOR
- CHECK DOWNLOAD PROGRAMMING – BYPASS
- RECORD DOWNLOAD PHONE NUMBER
- CHECK SYSTEM DATE & TIME
- RESET NEXT TIMER TEST (ATI)
- TEST INPUT VOLTAGE (Vac)
- TEST BATTERY UNDER LOAD VOLTAGE (Vdc)
- REPLACE BATTERY IF BELOW 12.20V UNDER LOAD OR 5 OR MORE YEARS OLD
- TEST & RECORD A SELECTION OF MOTION DETECTORS LOCALLY & REMOTELY
- TEST & RECORD A SELECTION OF PERIMETER DETECTION LOCALLY & REMOTELY
- TEST & RECORD A SELECTION OF DURESS & HOLDUP EQUIPMENT LOCALLY & REMOTELY
- TEST & RECORD A SELECTION OF SMOKE/THERMAL DETECTORS LOCALLY & REMOTELY
- SPRAY AROUND ALL DETECTION EQUIPMENT WITH INSECT SURFACE SPRAY
- TEST RF BATTERIES
- CONDUCT FUNCTIONAL RESET OPERATION
- CHECK SIRENS STOP AFTER CUT OFF TIME
- TEST PRIMARY COMMS TO MONITORING CENTRE
- TEST BACKUP COMMS TO MONITORING CENTRE (DUAL PATH ONLY)
- TEST 3RD COMMS TO MONITORING CENTRE (TRI-PATH ONLY)
- SYSTEM ALL RESTORED AND OPERATING CORRECTLY
- ALL WARNING SIGNAGE, STICKERS, & TELEPHONE LABELS ARE UPDATED & CORRECT
- NOTE ANY REPAIRS OR ADDITIONS REQUIRED
- CHECK ALL SIRENS AND STROBES WORKING
- CHECK A/C POWER IS ON
- LIST ANY ADDITIONAL WORKS OR CHECKS PERFORMED OR REQUIRED
- IMPORTANT CONCERNS NOTED TO CLIENT
- TECH’S NAME